Morin Standing Seam Series SWL-16

Morin Standing Seam Series SWL is offered in three widths; 12, 16 and 18 inches. With a concealed clip and fastener design, the SWL is perfectly suited for new or retrofit projects.

Lengths 5' (1.52m) to 40' (12.19m) standard Shorter and longer lengths available; Jobsite roll forming of panels in continuous lengths so as to eliminate panel end laps
Deliver panel materials and components in the original, unopened, undamaged packaging with identification labels intact. Store roof panel materials on dry, firm, and clean surface. Elevate one end of bundle to allow moisture run-off, cover and ventilate to allow air to circulate and moisture to escape. Install panels plumb, level, and true-to-line to dimensions and layout indicated on approved shop drawings. Remove protective film immediately following installation as per Morin's standard directions. Cutting and fitting of panels shall be neat, square and true. Torch or abrasive cutting is prohibited.
Architectural design concealed fastener standing seam roof
Weather-resistant or rainscreen rear-ventilated application
1 3/4"
44mm
16"
406mm
0.091666667
Steel (Galvalume/Zincalume) - 22 and 24 GA Aluminum - 0.040 GA and 0.032 GA Special Note: Copper, Zinc and Stainless Steel options available dependent on the profile.
Standard (Fluropon® PVDF-Kynar500®) Premium Colors MICA (Fluropon Classic®II PVDF) Premium Colors METALLIC (Fluropon Classic®PVDF) Morin Custom Color Matching Services Other Finishes Available
Smooth surface standard; Stucco embossed texture optional; striated and pencil beads are available
Factory caulking standard
SWL Sliding Clip available
Solid substrate required
Design Options for 0, 1 or 2 ribs
Bristol, CT, Fontana, CA, DeLand, FL And Onsite Roll Forming
Air Infiltration: ASTM E-283 and ASTM E-1680 Water Penetration: ASTM E-331, ASTM E-1646 Structural Performance: ASTM E-330 and ASTM E-1592 Wind Uplift Test: TAS 125-03 (UL580) Impact Testing: Class 1 -SH Hail Damage Resistance
West 22ga: 12" - 36 3/8"; 16" - 44 1/2"; 18" - 46 7/8"
Galvalume AZ-50 & Galvalume Plus AZ-55 & Zincalume 24 ga. (.023) = 1.46 # psf 22 ga. (.029) = 1.83# psf
Aluminum (3003 - H14) .032 (20ga.) = 0.66# psf .040 (18 ga.) = 0.82# psf
*The production of SWL in Copper, Zinc or Stainless Steel is dependent upon the substrate gauge and must be confirmed by MORIN Technical Department
*The production of SWL in Copper, Zinc or Stainless Steel is dependent upon the substrate gauge and must be confirmed by MORIN Technical Department
*The production of SWL in Copper, Zinc or Stainless Steel is dependent upon the substrate gauge and must be confirmed by MORIN Technical Department
Fluropon - 20 solid colors (Low Gloss) (1.0 mil - 2 coat) Fluropon Classic II - 5 mica colors (1.0 mil - 2 coat) Fluropon Classic - 4 metallic colors (1.5 mil- 3 coat) All material has 0.5 mil. Off-White backer
Off White Butyl (Non- Hardening)
E-5 Directional Pattern; Aztec Stucco Pattern EAST Only
12" long (std. length) Install behind panel with pop rivets and seal as req'd
22 pieces; 4 bndls wide on trailer 3 bndls high on trailer
22 1/4"W x 16 3/4"H
125 sqs.
Consult with Sales Office for available options and uses.
# 12 x 1 1/4" Tek 5 n/w (clip to steel) # 12 x 1 1/2" Tek 5 n/w 400 S/S # 12 x 1 Tek 3 n/w (clip to Sheet. Mtl) # 12 x 1" Tek 3 n/w 400 S/S #44 Pop Rivet 1/8" 400 S/S
Limited Finish Warranty 1 to 20 year Available at no charge (check specs for req'd years) Limited Material Warranty 1 to 20 year Available at no charge (check specs for req'd years) Limited (Roof) Weather Tight Warranty 1 to 20 year Available for addt'l charge (inspection and shop dwgs review req'd)

Images:


Rending (3D) Image
Project Image 1
Project Image 2
Project Image 3
Project Image 4